America West Drilling Supply...Where going in the hole makes sense!

|
Hurricane Boosters - Air or Nitrogen |

Model: B13-62
Hurricane boosters are second-to-none. They are smaller, lighter, and still pack as much power as the larger and heavier comparable units available in the marketplace today.
Our quality control and turnkey manufacturing process guarantee excellence, while superior engineering and design help drive custom solutions for our customers. Every feature that is built into our boosters shows you the experience, the power, the quality... the Hurricane difference.
Over 40 years of experience has taught us to maximize every component. Like all of our boosters, this unit provides you with a better penetration rate, cooler bit temperatures, and longer bit life.
Typical applications include: mineral exploration and blast hole drilling, coal bed methane drilling, oil and gas air/foam drilling, nitrogen generation, and pipeline services.
Specifications
| Booster |
|
B13-62/2175 |
| Booster type |
|
Model 414
6 cylinders
reciprocating
|
| Drive engine |
|
Caterpillar C13
440 bhp @ 1800 rpm
|
| Booster stages |
|
2 |
| Max. suction pressure |
psi |
350 |
| Max. discharge pressure |
psi |
2175 |
| Capacity at 350 psi |
cfm |
1-stage: 2900 2-stage: 1932 |
| Booster oil capacity |
gal.
|
5 |
| Engine oil capacity |
gal. |
9 |
| Fuel tank capacity |
gal. |
175 |
| Max. operating ambient temperature |
|
125° F |
| Wet weight |
lbs. |
15,080 |
| Overall dimensions, L x W x H |
in. |
180 x 88 x 89 |
| Suction connection |
|
4" npt |
| Discharge connection |
|
3" npt |
Standard Features
- Automatic load/unload system
- Booster bypass manifold
- Engine speed adjustment
- Double-acting concentric valves
- Staging valves on the 2-stage models
- Water-cooled booster and diesel engine
- Precooler (a+15°F) and suction scrubber tank
- Aftercooler (a+50°F)
|
- Heavy-duty skid with four-point lifting
- 24 volt DC starting and operating system
- Suction, interstage, and discharge safety relief valves
- Full function instrument panel monitoring all pressures, temperatures, and controls with full protection shutdown and fault indicators
|

Options:
- Automatic scrubber tank drain
- Cold weather kit (-20°F)
- Manual louvers in front of coolers
- Low pressure switch at booster inlet
- Lights for operation at night
- Weatherproof container
- Spark arrestor
- Overspeed shutdown
- Air starter
- Service pack 250 hrs/500 hrs/1000 hrs/2000 hrs
- Valve kits and piston kits
Other options, pressures, capacities available on request.

|